Deutsches Ozeanographisches
Datenzentrum Inventur der Alkor-Reise 357 (DOD-Ref-No.20100325)
Inventory of Alkor Cruise 357 (DOD-Ref-No.20100325)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Alkor 357 16.07.2010 - 25.07.2010 BLMP+
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Wasmund Norbert Leibniz-Institut fur Ostseeforschung, Warnemunde Rostock Rostock Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Monitoring cruise in the frame of the COMBINE programme of HELCOM

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Wasmund Norbert 14 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Chlorophyll a: Fluorometric method yes
IOW Nausch Gunther 12 stations B06
Dissolved organic matter (e.g. DOC)
DOC: TOC analyzer yes
IOW Jurgens Klaus 2 stations B07
Pelagic bacteria / micro-organisms
molecular biology: DNAy no
IOW Jurgens Klaus 2 stations B07
Pelagic bacteria / micro-organisms
molecular biology: FISH no
IOW Jurgens Klaus 2 stations B07
Pelagic bacteria / micro-organisms
ultraplankton counting: flow cytometry no
IOW Wasmund Norbert 14 stations B08
Phytoplankton
Phytoplankton species and biomass: microscopical counting yes
IOW Wasmund Norbert 9 stations B09
Zooplankton
Zooplankton species and abundance: microscopical counting yes
IOW Nausch Gunther 12 stations B71
Particulate organic matter (e.g. POC, PON)
POC: CHN analyzer yes
IOW Wasmund Norbert 70 stations H00
Stations
- yes
IOW Feistel Sabine 64 stations H09
Water bottle stations
Rosette samplers no
IOW Feistel Sabine 74 stations H10
CTD-Stations
CTDO casts: Temperature, salinity, oxygen, sound velocity, fluorescence yes
IOW Wasmund Norbert 12 stations H16
Transparency (e.g. transmissometer)
Secchi depth no
IOW Nausch Gunther 63 stations H21
Oxygen
Oxygen: potentiometric titration yes
IOW Nausch Gunther 39 stations H22
Phosphates
Phosphate: nutrient analyzer (colorimetric method) yes
IOW Nausch Gunther 12 stations H23
Total - P
Total P: acid persulfate oxydation followed by phosphate determination yes
IOW Nausch Gunther 39 stations H24
Nitrates
Nitrate: nutrient analyzer (colorimetric method) yes
IOW Nausch Gunther 39 stations H25
Nitrites
Nitrite: nutrient analyzer (colorimetric method) yes
IOW Nausch Gunther 39 stations H26
Silicates
Silicate: nutrient analyzer (colorimetric method) yes
IOW Nausch Gunther 12 stations H75
Total-N
Total N: persulfate oxydation followed by nitrate determination yes
IOW Nausch Gunther 12 stations H76
Ammonia
Ammonia: manually (colorimetric standard method) yes
IOW Pohl C. 10 stations P02
Trace metals
Trace Metals: Atom absorption yes
IOW Schulz-Bull Detlef E. 17 stations P04
Chlorinated hydrocarbons
HCH/CKW/PAK: gas chromatography, yes
IOW Schulz-Bull Detlef E. 8 stations P90
Other contaminant measurements
- yes
13.4.2024