Deutsches Ozeanographisches
Datenzentrum Inventur der Alkor-Reise 313 (DOD-Ref-No.20080042)
Inventory of Alkor Cruise 313 (DOD-Ref-No.20080042)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Alkor 313 10.02.2008 - 20.02.2008 BLMP+
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Nagel Klaus Leibniz-Institut fur Ostseeforschung, Warnemunde Warnemunde Warnemunde Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Study of spatial and temporal variations of hydrographic, hydrochemical and biological parameters in the frame of the COMBINE Programme of HELCOM , combined with long term observations of IOW

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Wasmund Norbert 15 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Phytoplankton Pigments no
IOW Wasmund Norbert 18 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Chlorophyll, Phaephytin yes
IOW Nagel Klaus 10 stations B06
Dissolved organic matter (e.g. DOC)
Dissolved organic matter no
IOW Wasmund Norbert 14 stations B08
Phytoplankton
Phytoplankton yes
IOW Wasmund Norbert 15 stations B09
Zooplankton
Zooplankton no
IOW Nagel Klaus 10 stations B71
Particulate organic matter (e.g. POC, PON)
Particulate organic matter (POC , PON) no
IOW Wasmund Norbert 18 stations B80
Other bio-measurements
Phaeopigment yes
IOW Nagel Klaus 60 stations H00
Stations
- yes
IOW Feistel Rainer 56 stations H09
Water bottle stations
Fluorescence no
IOW Feistel Rainer 81 stations H10
CTD-Stations
CTD-casts / rosette samples & sensors for oxygen yes
IOW Wasmund Norbert 14 stations H17
Optics (e.g. underwater light levels)
Secci yes
IOW Nausch Gunther 56 stations H21
Oxygen
Winkle titration , potentiometric titration yes
IOW Nausch Gunther 56 stations H22
Phosphates
Colorimetric standard procedure (Autoanalyzer) - phosphates yes
IOW Nausch Gunther 10 stations H23
Total - P
Acid persulphate oxidation - phosphate determination yes
IOW Nausch Gunther 56 stations H24
Nitrates
Colorimetric standard procedure (Autoanalyzer) - nitrates yes
IOW Nausch Gunther 56 stations H25
Nitrites
Colorimetric standard procedure (Autoanalyzer) - nitrites yes
IOW Nausch Gunther 56 stations H26
Silicates
Colorimetric standard procedure (manual) - ammonia yes
IOW Nausch Gunther 6 stations H33
Other dissolved gases
Hydrogen sulphide no
IOW Nausch Gunther 10 stations H75
Total-N
Acid persulphate oxidation - nitrate determination yes
IOW Nausch Gunther 56 stations H76
Ammonia
Colorimetric standard procedure (manual) - ammonia yes
IOW Pohl C. 9 stations P02
Trace metals
Trace elements yes
IOW Schulz-Bull Detlef E. 10 stations P04
Chlorinated hydrocarbons
Chlorinated hydrocarbons yes
IOW Schulz-Bull Detlef E. 14 stations P90
Other contaminant measurements
Polyaromatic hydrocarbons (PAH) no
20.4.2024