Deutsches Ozeanographisches
Datenzentrum Inventur der Gauss-Reise 462 (DOD-Ref-No.20060210)
Inventory of Gauss Cruise 462 (DOD-Ref-No.20060210)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
Gauss 462 18.07.2006 - 28.07.2006 BLMP+
COMBINE
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Nausch Gunther Leibniz-Institut fur Ostseeforschung, Warnemunde Warnemunde Warnemunde Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Studies of the spatial and temporal variations of hydrographic, hydrochemical and hydrobiological parameters in the frame of the COMBINE Programme of HELCOM

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Wasmund Norbert 19 stations B02
Phytoplankton pigments (e.g. chlorophyll, fluorescence)
Chlorophyll determination, other pigments yes
IOW Nausch Gunther 14 stations B06
Dissolved organic matter (e.g. DOC)
TOC-analyzer no
IOW Wasmund Norbert 14 stations B08
Phytoplankton
net sample, full sample, different depths yes
IOW Wasmund Norbert 8 stations B09
Zooplankton
Plankton net, mesh size 100?m yes
IOW Nausch Gunther 14 stations B71
Particulate organic matter (e.g. POC, PON)
CHN-analyzer no
IOW Nausch Gunther 96 stations H00
Stations
- yes
IOW Feistel Rainer 78 stations H10
CTD-Stations
CTD casts + sensors for oxygen, sound, fluorescence and turbidity yes
IOW Nausch Gunther 13 stations H17
Optics (e.g. underwater light levels)
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 69 stations H21
Oxygen
Oxygen, Winkler method, potentiometric titration yes
IOW Nausch Gunther 37 stations H22
Phosphates
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 14 stations H23
Total - P
Persulphate oxidation followed by phosphate determination yes
IOW Nausch Gunther 37 stations H24
Nitrates
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 37 stations H25
Nitrites
Colorimetric standard method (autoanalyzer) yes
IOW Nausch Gunther 37 stations H26
Silicates
Colorimetric standard method (autoanalyzer) yes
BSH Herrmann J. 4 stations H31
Radioactivity
Radioactivity in water yes
IOW Nausch Gunther 13 stations H33
Other dissolved gases
Hydrogen sulphide (colorimetric method) no
IOW Nausch Gunther 14 stations H75
Total-N
Persulphate oxidation followed by nitrate determination yes
IOW Nausch Gunther 14 stations H76
Ammonia
Colorimetric standard method (manual) yes
IOW Nausch Gunther 1 n miles H80
Other physical measurements
Underway measurements during the whole trip programm DATADIS yes
20.4.2024