Deutsches Ozeanographisches
Datenzentrum Inventur der A. v. Humboldt-Reise 96-03 (DOD-Ref-No.19960192)
Inventory of A. v. Humboldt Cruise 96-03 (DOD-Ref-No.19960192)

Plattform
Platform
Reise-Nr.
Cruise-No.
Zeitraum
Period
Projekt
Project
Arbeitsgebiet
Working area
A. v. Humboldt 96-03 12.02.1996 - 26.02.1996 BMP
 
Baltic Sea  

Fahrtleiter
Chief Scientist
Institut
Institute
Auslaufhafen
Port of departure
Einlaufhafen
Port of return
Stationskarte
Station map
Schiffsroute
Trackchart
Nagel Klaus Leibniz-Institut fur Ostseeforschung, Warnemunde Rostock Rostock Karte
Map
 

Ziel der Reise / Objectives of Cruise:

Study of the spatial and temporal variations of hydrographic and hydrochemical parameters in the frame of the Baltic Monitoring Programme (BMP) and the Coastal Monitoring Programme (CMP) of the HELCOM.

Messungen / Measurements

Institut
Institute
Wissenschaftler
Scientist
Anzahl
Number
Einheit
Unit
Typ der Messungen
Type of measurements
Kommentar
Comments
Daten im DOD
Data in DOD
IOW Nagel Klaus 15 stations B06
Dissolved organic matter (e.g. DOC)
- no
IOW Nagel Klaus 15 stations B71
Particulate organic matter (e.g. POC, PON)
- no
IOW Nagel Klaus 86 stations H00
Stations
- no
IOW Lass Ulrich 60 stations H09
Water bottle stations
Rosette samples yes
IOW Lass Ulrich 91 stations H10
CTD-Stations
CTD casts + sensors for oxygen sound velocity, fluorescence yes
IOW Nagel Klaus 60 stations H21
Oxygen
Winkler titration, potentiometric tritration yes
IOW Nagel Klaus 42 stations H22
Phosphates
Clorimetric stand. procedure (manual & autoanalyzer) yes
IOW Nagel Klaus 13 stations H23
Total - P
Acid persulphate oxidation---phosphate determ. yes
IOW Nagel Klaus 42 stations H24
Nitrates
Colorimetric stand. procedure (manual & autoanalyzer) yes
IOW Nagel Klaus 42 stations H25
Nitrites
Colorimetric stand. procedure (manual & autoanalyzer) yes
IOW Nagel Klaus 60 stations H26
Silicates
Colorimetric stand. procedure (manual & autoanalyzer) yes
IOW Nagel Klaus 75 stations H28
PH
pH-meter, glass electrode no
IOW Nagel Klaus 9 stations H33
Other dissolved gases
Hydrogen sulphide no
IOW Schneider Bernd 26 stations H74
Carbon dioxide
- no
IOW Nagel Klaus 13 stations H75
Total-N
Persulphate oxidation, nitrate determ. yes
IOW Nagel Klaus 13 stations H76
Ammonia
Colorimetric stand. procedure (manual & autoanalyzer) yes
IOW Pohl C. 17 stations P02
Trace metals
- yes
IOW Dannenberger G. 20 stations P04
Chlorinated hydrocarbons
- no
IOW Dannenberger G. 20 stations P90
Other contaminant measurements
Polyaromatic hydrocarbons (PAH's) no
20.4.2024